F lling aircraft on-board O* cylinders for commercial, military and private fleets. Transferring O? into various high pressure receivers for deep ocean diving support, commercial or military. These are just two examples of the uses for Model 26968 oxygon boosters that have provided cost savings and increased safety for many years. This model will pump from high or medium pressure sources and will also function effectively to collect and transfer the gas from partially depleted supply cylinders to "top off’1 other cylinders to maximum pressure. Conventional industrial, shipboard or contractor typo compressed air sources are normally used for power. All motive power and controls are completely pnejmatic with no electrical con n ecti o ns req u i red.
The basic booster is two-stage: rated for continuous duty compression ratios of over 15:1, intermittent to 40:1.
A pneumatic control package continually monitors both inlet cylinder pressure and outlet receiver pressure, stopping the booster automatically when desired outlet or minimum inlet pressure is reached, permitting unattended operation.