OverviewThe award-winning PulseVentilation system delivers high energy efficiency and installation flexibility for parapet/sill applications. The FVPpulse-V parapet unit enables cost-effective refurbishments and new builds where only a single façade opening is available, eliminating the need for raised floors or suspended ceilings. The pulse ventilation principle creates organic air movement for natural breathing of the building while providing year-round heat and cold recovery and high thermal comfort.
Key features- Decentralized heating, cooling, dehumidification and filtration via pulsating ventilation through a single façade opening
- Highly economical thanks to efficient heat recovery (up to ~90 %) and demand-oriented control strategies
- Draught-free, low-noise impulse flow up to 130 m³/h (260 m³/h in hybrid mode) with high ventilation efficiency
- Space savings by removing central AHUs, shafts, ductwork and fire dampers
- Very low electrical consumption due to minimized pressure losses (≈10 % of EnEV SFP specification; ≈20 W per device typical)
- Year-round heat recovery reduces sizing and cost of central heating systems
Operation modes & concepts- Demand ventilation: pulsating/instationary operation alternates supply and extract between devices for decentralized ventilation without sustained room over- or underpressure (Master–Slave communication supported)
- Hybrid ventilation: supply-only operation up to 260 m³/h to cover peak cooling loads (e.g., exhaust via window) — nearly doubles cooling capacity and outside-air flow with comparable acoustics
- Night ventilation: stationary mode for cool-night ventilation without open windows; heat recovery bypassed for maximum cooling
Technical data (summary)Data for LpA = 35 dB(A):
- Average cyclic volume flow up to 130 m³/h
- Volume flow up to 260 m³/h in hybrid mode
- Condensing operation: standard
- Max cooling output (total): 835 W; room share ≈ 595 W
- Max heating output (total): 2125 W; room share ≈ 765 W
- Heat recovery > 80 % (configurations up to ≈ 90 %)
- Electrical consumption: 12–40 W depending on operating point
- Sound pressure level Lp(A): 23–36 dB(A)
Dimensions (Length x Width x Height)1053 x 335 x 763 mm
Additional informationDWG, dimensioning tools, technical brochures and short product datasheets are available for download with performance charts and installation guidance.
Technical specifications- Model family: FVPpulse (parapet/sill installation variant: FVPpulse-V)
- Application: decentralized ventilation with heat recovery for refurbishment and new build where façade-only opening is required
- Average cyclic supply air volume: up to 130 m³/h
- Hybrid mode supply air volume: up to 260 m³/h
- Heat recovery: >80 % (up to ≈90 % in certain configurations)
- Cooling capacity (max, total): 835 W; room share ≈595 W
- Heating capacity (max, total): 2125 W; room share ≈765 W
- Electrical consumption range: 12–40 W
- Acoustic levels: Lp(A) typically 23–36 dB(A); example sound power level 45 dB(A)
- Dimensions (L×W×H): 1053 × 335 × 763 mm
- Water-side examples used in dimensioning: typical mass flows ~150–200 kg/h (configurable)
- Supported concepts: demand ventilation, hybrid ventilation, night ventilation
- Suitable for parapet/sill installation without raised floors or suspended ceilings