Short descriptionSafeagle HP-SE6550C high-performance X-ray baggage scanner with switchable 4/7-color imaging and dual-energy detection, suitable for checkpoints, transport hubs and public facilities.
OverviewThe Safeagle HP-SE6550C is a compact, high-performance X-ray baggage scanner engineered for reliable threat detection. It provides switchable 4/7-color imaging to assist material discrimination by mapping atomic number ranges to specific colors. The Zeff-scan function highlights potential explosive and narcotic threats (Zeff 7, 8, 9) in real time, improving operator identification of suspicious items. Dual-energy imaging differentiates organic and inorganic materials by color (for example metallic items in blue, organic materials in orange). The system supports split-screen and full-screen display modes with independent color-mode settings for main and auxiliary screens.
Features- Switchable 4/7 Colors Imaging
- Real-time image processing
- Organic, inorganic and mixed-material striping
- Hazardous liquid assistance (Zeff 6)
- Explosive and narcotic assistance (Zeff 7,8,9)
- Thin-object and splicing scanning
GENERAL SPECIFICATIONS- Tunnel Size: 654(W) x 508(H) mm
- Overall Dimensions: 1691(L) x 985(W) x 1275(H) mm
- Conveyor Maximum Load: 165 kg
- Belt Speed: 0.23 m/s (bidirectional)
X-RAY GENERATOR- Voltage: 140 kV
- Wire Detectability: 40 AWG
- Spatial Resolution: 1.0 mm Horizontal, 1.0 mm Vertical
- Steel Penetration: 36 mm (typical)
- Tube Current: 0.7 mA
- Cooling Method: Sealed oil bath with forced air
- Duty Cycle: 100% (no warm-up required)
- Beam Direction: Diagonally upward
- Detector Type: L-shaped array
- Dual-energy: Yes
WORKING ENVIRONMENT- Operating Temperature: 0°C – 40°C (32°F – 104°F)
- Storage Temperature: -20°C – 60°C (-4°F – 140°F)
- Humidity: Up to 95% non-condensing
- Power Requirements: 220 VAC ±10%, 50/60 Hz, 10 A max
TECHNICAL SPECIFICATIONS- Tunnel Size: 654(W) x 508(H) mm
- Dimensions: 1691(L) x 985(W) x 1275(H) mm
- Maximum Conveyor Load: 165 kg
- Belt Speed: 0.23 m/s (bidirectional)
- X-ray Voltage: 140 kV
- Wire Detectability: 40 AWG
- Spatial Resolution: 1.0 mm (H) x 1.0 mm (V)
- Typical Steel Penetration: 36 mm
- Tube Current: 0.7 mA
- Cooling: Sealed oil bath with forced air
- Duty Cycle: 100% (no warm-up required)
- Beam Direction: Diagonally upward
- Detector: L-shaped array
- Dual-energy imaging: Yes
- Operating Temperature Range: 0°C to 40°C
- Storage Temperature Range: -20°C to 60°C
- Allowed Humidity: up to 95% non-condensing
- Power Supply: 220 VAC ±10%, 50/60 Hz, 10 A max