Saturated Steam: Achieves 100% RH via pressurized pure water vapor.
Pressure Range: 0.1 MPa to 0.3 MPa (1–3 atm)
Cycle Duration: 24–168H (accelerated aging equivalent to 1,000H+ in standard 85°C/85% RH tests).
2 - Internal Dimensions
(Diameter ×D)mm - Ф300x250 - Ф450x300 - Ф500x450 - Ф650x600
3 - External Dimension
WxHxD (mm) - 500x500x700 - 580x850x650 - 800x750x900 - 950x900x1100
5 - Temperature Fluctuation - ≤ ± 0.5℃
6 - Temperature Uniformity - ≤ 1.5℃
7 - Humidity Range -
100%R.H Saturated vapor
Or:
70 ~100%R.H (Steam humidity adjustable)
8 - Humidity Uniformity - ± 1.5% RH
9 - Humidity Uniformity - ± 3.0% RH
10 - Pressure range - 0 to +2 kg/cm² (Operational range: 0 to +3 kg/cm²)
Absolute Pressure Range: 1.0-3.0 kg/cm²
Safety Pressure Capacity: 4 kg/cm² Equal to
1 atmospheric pressure + 3 kg/cm² gauge pressure
11 - Circulation Mechanism - Natural convection of water vapor
12 - Test Time Setting - Programmable duration: 0-999 hours
13 - Pressurization Time - Achieves 0.00→2.00 kg/cm² in ≈30 min
(non-linear ramp under no-load conditions)
14 - Temperature Ramp Profile - Ambient→132℃ in ≈30 min
(air temperature-based control, not product temperature)
15 - Safety Protections - Dual-mode Water Management
(Automatic/manual water replenishment, Automatic pressure relief)
Critical Safeguards
(Low-water cutoff protection,Overpressure interlock)
16 - Power - AC220V; 1phase 3 lines ; 50/60HZ
AC380V; 3phase 5 lines ; 50/60HZ
Product Features
Features
1.Hyper-Accelerated Aging:
•Combines high temperature, 100% RH, and pressure to simulate decades of environmental degradation in days.