- Runways, Taxiways - Ground Support >
- Aircraft ground support >
- Hangar ground power unit
Hangar ground power units
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

Voltage: 115, 200, 28 V
Frequency: 400 Hz
Power: 140, 90 kVA
Engine: Deutz / Cummins / John Deere Dimensions: 3300 x 1880 x 1790 mm Weight: 2700 kg The Guinault GPUs provide power to the aircraft in accordance with aircraft manufacturers' recommendations and standards in force. ...
GUINAULT S.A FRANCE

Voltage: 28, 115, 200 V
Frequency: 400 Hz
Power: 180, 90 kVA
... 165 kWh Dimensions: 3460 x 2130 x 1680mm Weight: up to 4100kg (depends on battery capacity) The Guinault GPUs provide power to the aircraft in accordance with aircraft manufacturers' recommendations and standards ...
GUINAULT S.A FRANCE

Voltage: 28, 400 V
Frequency: 60, 50 Hz
Dimensions: 1680 x 1200 x 956 mm Weight: 450 kg (without cable] Os GPU Guinault asseguram a alimentação elétrica das aeronaves, conforme as recomendações dos fabricantes de aeronaves e as normas em vigor. Fornecem ...
GUINAULT S.A FRANCE

Frequency: 400 Hz
Power: 90 kVA
ECOTUG 90 battery-powered eGPU delivers clean and stable 400Hz power, serving as a sustainable alternative to fuel-powered GPUs. This all-in-one unit integrates a high-performance power ...

Voltage: 29 V
The APA-65 (EAR-600) is ElectroAir’s rugged diesel Ground Power Unit engineered to supply stable 28.5 VDC output in harsh, isolated, or mobile airfield conditions. Powered by a reliable Deutz Stage V ...
ELECTROAIR

Voltage: 28 V
Frequency: 400 Hz
Power: 45 kVA
... enclosure and smart touchscreen interface, the APA-65 Hybrid unit adapts easily to a wide variety of field environments - from remote helipads to busy regional airports. It supports both DC and AC-powered ...
ELECTROAIR

Voltage: 28 V
... fully electric, battery-powered GPU engineered for zero-emission aircraft ground support. With its reliable 28.5 VDC output and silent operation, this unit is the optimal choice for eco-sensitive ...
ELECTROAIR

Voltage: 14 V - 400 V
... voltage 100…240VAC Charging and battery status displays Main battery switch for switching on/off the on-board power supply Respectively 1.5m charging and on-board power ...
RECK SOLAR und ELME ELEKTROMECHANIK GmbH

... a proper unit available. Also with additional options like service outlet, variant cable set, etc. From portable small units -as attendant for the pilot-, over the hangar models ...
RECK SOLAR und ELME ELEKTROMECHANIK GmbH

Voltage: 28, 200, 115 V
Power: 800 kVA - 2,400 kVA
Hangarmodel- or Apronmodel with 800A Peak 2400A High short-time and peak power With high-quality DC voltage, covers all the power requirements for the lighting, air-conditioning, ...
RECK SOLAR und ELME ELEKTROMECHANIK GmbH

Voltage: 115 V
Frequency: 400 Hz
Power: 140 kVA
... that needs power. Performance: Superior performance compared to traditional fuel models, ensuring stable and reliable power for the aircraft during ground operations. Sustainability: ...

Voltage: 115 V
Frequency: 400 Hz
Power: 90 kVA
... that needs power. Performance: Superior performance compared to traditional fuel models, ensuring stable and reliable power for the aircraft during ground operations. Sustainability: ...

Voltage: 115 V
Frequency: 400 Hz
Power: 180 kVA
... that needs power. Performance: Superior performance compared to traditional fuel models, ensuring stable and reliable power for the aircraft during ground operations. Sustainability: ...

Voltage: 28 V
Frequency: 400 Hz
Power: 45 kVA - 180 kVA
Ground power right where you need it with Jetpower mobile, diesel or electric powered, 400 Hz and 28VDC ground power carts. The Jetpower family of mobile ...
OSHKOSH AEROTECH

Voltage: 28 V
Frequency: 400 Hz
Power: 90 kVA
... push buttons for operation of the retriever and the connected 400 Hz power unit. ITW GSE 2400 Cable Retriever The cable retriever can be connected to any 400 Hz ...
ITW GSE

Voltage: 380 V - 480 V
Frequency: 400 Hz
Power: 20 kVA - 45 kVA
... aircraft ground power applications in the hangar or ramp area. The dual output AC/DC PwrKart provides simultaneous AC and DC power from a single GPU. Kilowatt power ...
UNITRON POWER SYSTEMS

Voltage: 28, 26, 24 V
Frequency: 50, 60 Hz
... 300 is a 28V DC ground power unit, (GPU), designed for use in aircraft hangars, congested ramps and busy gate areas where space is limited. Regional ...

Voltage: 345, 200, 28, 220, 380 V
Frequency: 400, 60, 50 Hz
Power: 90, 45, 60, 30 kVA
... efficiency coefficient Low power consumption Low noise level Robust design Designed to comply with RoHS and REACH requirements Combined power unit FCA-90/AR-600A consists of frequency ...
TALLINN ELECTRICAL ENGINEERING FACTORY ESTEL
Your suggestions for improvement:
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how AeroExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining