{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Voltage: 115 V
Frequency: 400 Hz
Power: 90 kVA
... ECOTUG 90 battery-powered eGPU delivers clean and stable 400Hz power. This all-in-one unit integrates a high-performance power system with a towable chassis. As the latest generation ...
AEME GSE
Voltage: 115 V
Frequency: 400 Hz
Power: 90 kVA
... The S400-A briege-mounted
GPU integrates a solid-state
ground
power unit with an automatic 28-meter cable coiling device into a compact, all-in-one system — ideal for boarding bridge installations.
At ...
AEME GSE
Voltage: 115 V
Frequency: 400 Hz
Power: 90 kVA
... The S400-M solid-state
power
unit offers flexible configuration options, including a towable trailer, making it well-suited for both remote and contact stand operations.
At the heart of the S400-A lies AEME’s independently ...
AEME GSE
Power: 90 kVA
... Overview
The GPU-409-iHS is a hybrid solid-state mobile
ground
power unit (GPU) delivering
90
kVA. It combines onboard lithium battery energy storage with a 19 kW GENSET that ...
Voltage: 28 V
Frequency: 400 Hz
Power: 90 kVA - 180 kVA
... point-of-use ground power units supply 400 Hz or 28VDC power where you want it, right where it's needed – close to the aircraft. Designed to be stand or boarding bridge mounted, Jetpower units ...
Voltage: 200, 115 V
Frequency: 400 Hz
Power: 90 kVA
... above sea level: less than 4000m Capacity 90 KVA Rated voltage115/200V Rated frequency400Hz Power factor0.8 Voltage regulation114116V Modulation3.5V Cold and hot state voltage drift±1% Transient surge ...
Voltage: 114 V - 116 V
Frequency: 400 Hz
Power: 90 kVA
... Technical Specifications: Capacity: 90 KVA Rated voltage:115/200V Rated frequency:400Hz Power factor:0.8 Voltage regulation:114~116V Modulation:3.5V Cold and hot state voltage drift:±1% Transient ...
Voltage: 115 V
Frequency: 400 Hz
Power: 90, 60 kVA
... pressure air parameter Pressure Psig:41 High pressure air parameter Temperature ℃:200±10 Alternating current Capacitance kVA: 90 Alternating current Voltage V:28. 5 Alternating current Capacitance A:600 ...
Voltage: 115, 200, 28 V
Frequency: 400 Hz
Power: 140, 90 kVA
... Engine: Deutz / Cummins / John Deere Dimensions: 3300 x 1880 x 1790 mm Weight: 2700 kg The Guinault GPUs provide power to the aircraft in accordance with aircraft manufacturers' recommendations and standards in force. They deliver ...
Guinault
Voltage: 200, 115 V
Frequency: 400 Hz
Power: 180 kVA
... Engine: Deutz / Cummins / John Deere Dimensions: 3300 x 1880 x 1790 mm Weight: 2700 kg The Guinault GPUs provide power to the aircraft in accordance with aircraft manufacturers' recommendations and standards in force. They deliver ...
Guinault
Voltage: 28, 115, 200 V
Frequency: 400 Hz
Power: 180, 90 kVA
... 165 kWh Dimensions: 3460 x 2130 x 1680mm Weight: up to 4100kg (depends on battery capacity) The Guinault GPUs provide power to the aircraft in accordance with aircraft manufacturers' recommendations and standards in force. They deliver ...
Guinault
Voltage: 28 V - 200 V
Frequency: 50, 60, 400 Hz
Power: 1 kVA - 360 kVA
... The FR-400/28 Series Combined
Units are designed to
power on-board systems of aircraft and helicopters during
ground handling at airports, shop floors, and training centers.
• AC 400 Hz up to 360 ...
Voltage: 270 V
Frequency: 400 Hz
Power: 90 kVA
... aircraft
power quality requirements
Designed for fifth-generation military aircraft
ground operations
Single Output
Rated output
power up to
90 kW
Output ...
Voltage: 28 V
Frequency: 400, 50 Hz
Power: 90 kVA
... Series Underbridge Unit Sets supply aircraft during preflight preparation and maintenance. It is installed under the passenger boarding bridge and provides: The unit ensures reliable, stable and safe electrical supply ...
Voltage: 380, 400 V
Frequency: 400 Hz
Power: 90, 120, 150, 180 kVA
... ; the first unit to power on becomes master. Intelligent control automatically starts/stops units according to load or aircraft count. In case of a unit failure, the ...
Voltage: 380, 400 V
Frequency: 400 Hz
Power: 90 kVA
... Combined Drum Ground Power Unit is a 400 Hz all-in-one GPU integrating a solid-state power conversion unit with a motorized cable reel. Designed for plug-and-play airport ...
Voltage: 400, 380 V
Frequency: 400 Hz
Power: 90, 180 kVA
... Product overview
AN17ES(F) Series
ground solid-state
power supply is an energy-storage
ground
power unit (GPU) designed for aircraft with 400Hz electrical systems. The
unit ...
Voltage: 29 V
Frequency: 400 Hz
Power: 90 kVA
... Other diesel
GPU models (examples)
- APA-10 – compact diesel GPU (28.5 VDC)
- APA-65 (EAR-600) – mobile diesel ground power unit
- APA-110 –
Voltage: 115 V
Frequency: 400 Hz
Power: 90 kVA
... that needs power. Performance: Superior performance compared to traditional fuel models, ensuring stable and reliable power for the aircraft during ground operations. Sustainability: Using electricity ...
Voltage: 200, 115 V
Frequency: 400 Hz
Power: 90 kVA
... DESIGNED PERFECTLY FOR YOU? For years we have chosen to use an integrated approach to create a final version of the Ground power units: In the first part of the process, we deal entirely with designing ...
Voltage: 380, 415, 28 V
Frequency: 50, 400 Hz
Power: 90, 180, 120, 140 kVA
... Controls and operation are easy and user friendly, thanks to the high precision 7 “LCD supervision touch screen display, on the unit front command and control panel. No emissions Max reliability Silent operation Significant savings ...
Voltage: 28, 200, 115 V
Frequency: 400 Hz
Power: 90 kVA
... The unit has been designed focusing on client real needs and manufactured following EFFETI quality standard, the GPU ( Ground Power Units) 400Hz EFFETI serie FT99 is intended ...
Voltage: 115, 200, 380, 415, 28 V
Frequency: 400, 50, 60 Hz
Power: 90, 140, 180 kVA
... EFFETI designs and manufactures ELECTRICAL ROTATING GPUs ( Ground Power Units) for outdoor use, which can convert electrical power supplied by the normal distribution network into energy ...
Voltage: 28 V
Frequency: 400 Hz
Power: 30 kVA - 180 kVA
... The ITW GSE 2400 Compact GPU is the market’s best choice for point-of-use 400 Hz solid-state ground power units (GPU). It is small and simple, reliable and robust. This 400 Hz frequency ...
ITW GSE
Voltage: 200 V
Frequency: 400 Hz
Power: 90 kVA
... page): 90 kVA — 400 Hz configuration
Sinepower
Voltage: 115, 200 V
Power: 90, 140, 120, 180 kVA
... maintenance Dynell's diesel-driven ground power units are built to last. The innovative design withstands the harshest conditions at the apron. Due to the thought-out product concept, which is based on the experience ...
Voltage: 380 V - 480 V
Frequency: 400 Hz
Power: 45 kVA - 90 kVA
... regulated and line drop compensated, and configured for partial redundancy. These 400Hz Ground Power Units (GPUs) range from 20 kVA to 180 kVA. Dependent upon rating, these units ...
UNITRON POWER SYSTEMS
Voltage: 115, 480, 315, 400, 200 V
Frequency: 400, 50, 60 Hz
Power: 90 kW
... worldwide by local staff. From conception, the SAS's PV 90-4 was designed to be a zero downtime GPU requiring a minimum of planned maintenance. Unity output power factor 95%* efficiency Stainless ...
Voltage: 345, 200, 28, 220, 380 V
Frequency: 400, 60, 50 Hz
Power: 90, 45, 60, 30 kVA
... efficiency coefficient Low power consumption Low noise level Robust design Designed to comply with RoHS and REACH requirements Combined power unit FCA- 90/AR-600A consists of frequency ...
TALLINN ELECTRICAL ENGINEERING FACTORY ESTEL
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how AeroExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group